YX-ZR9705 Automatic Calorimeter
Standard instrument configuration:
1 computer + 1 printer + 1 set of YX-ZR9705 host unit
Category:
Calorific Value Analysis Series
Measurement of the Calorific Value of Coal
Keywords:
Analysis instrument
- Product Description
- Technical Features
- Technical Specifications
-
- Commodity name: YX-ZR9705 Automatic Calorimeter
- 仪器标准配置: 1 computer + 1 printer + 1 set of YX-ZR9705 host unit
- 技术特点: It employs five probes for real-time temperature sensing, continuously monitoring the outer cylinder, inner cylinder, temperature‑control water tank, constant‑temperature water tank, and ambient room temperature throughout the test, thereby achieving automatic adjustment of both the inner and outer cylinder temperatures.
It is primarily suitable for calorific value analysis of solid or liquid combustible materials, including coal, coke, petroleum, biomass fuels, cement clinker, and solid/hazardous wastes.
Scope of Application
It is primarily suitable for calorific value analysis of solid or liquid combustible materials, including coal, coke, petroleum, biomass fuels, cement clinker, and solid/hazardous wastes.
Conform to the standards
GB/T 213 “Method for Determination of Calorific Value of Coal”
GB/T 384 “Method for Determination of Calorific Value of Petroleum Products”
GB/T 483 “General Provisions for Coal Analysis Test Methods”
JC/T 1005 “Method for Determining the Calorific Value of Cement Raw Meal”
GB/T 30991 “General Technical Requirements for Intelligent Oxygen Bomb Calorimeters”
ASTM D5865 “Standard Test Method for Gross Calorific Value of Coal and Coke”
GB/T 30727 “Method for Determining the Calorific Value of Solid Biomass Fuels”
GB/T 14402 “Determination of the Combustion Performance and Calorific Value of Building Materials and Products”
ISO 1928 “Solid Mineral Fuels — Determination of Gross Calorific Value by Bomb Calorimetry and Calculation of Net Calorific Value”
Key words: -
Core Advantages
Its core testing performance, accuracy, and stability are fully consistent with the 9706 model, meeting all national standard methods; the only difference is that it omits the automatic oxygen‑injection module, which does not affect daily efficiency at all and still delivers precise, reliable test results.
Technical Features
◎ Utilizes four probes for real-time temperature sensing, continuously monitoring the outer cylinder, inner cylinder, temperature‑control water tank, and ambient room temperature during testing, thereby enabling automatic adjustment of both the inner and outer cylinder temperatures.
◎ Equipped with an MCPC control module, the instrument provides real-time status monitoring, saves parameter settings, and autonomously completes test procedures without requiring host‑computer intervention, enabling standalone operation and self‑diagnostic alerts, thereby significantly enhancing instrument reliability.
◎ Equipped with a novel automatic oxygen bomb lifting mechanism, the oxygen bomb is raised and lowered automatically, offering a high degree of automation and simple, convenient operation.
◎ Employs automatic oxygen bomb identification technology to automatically determine the heat capacity of each oxygen bomb.
◎ A pump‑circulation system is employed to ensure uniform temperature distribution throughout the calorimeter, thereby guaranteeing the accuracy of the test results.
◎ Utilizes thermal insulation materials to isolate the instrument from external environmental influences, resulting in strong anti-interference performance.
◎ Employs a probe-type electronic measuring cup for automatic measurement of the inner cylinder’s water volume. Repeatability error is less than 0.5 g, with short test times and accurate results.
◎ Automatic ignition wire detection function, accurately identifying defective ignition wires;
◎ Equipped with a water filtration system to prevent impurities from clogging the water lines;
◎ Depending on the laboratory’s working conditions, the benchtop and upright configurations can be interchanged.
◎ Can be integrated with the laboratory management system to ensure that balance data is never stored locally and that test results are backed up and uploaded.
◎ For solid waste samples, optional accessories such as a specially designed oxygen bomb and crucible are available.
◎ An oxygen bomb gas collection device is available as an optional accessory for collecting gases inside the oxygen bomb.
-
Temperature measurement range: 5°C to 40°C
Precision: ≤0.1%
Heat capacity stability: Heat capacity variation within one year ≤ 0.2%
Accuracy: Better than that specified in GB/T 213, “Method for Determination of Calorific Value of Coal”
Temperature resolution: 0.0001℃
Single-sample test time: ≤13 min (conventional method), ≤10 min (rapid method)
Power supply: AC 220 V ± 22 V / 50 Hz
Power: ≤0.8 kW
Master carton dimensions (mm): 520×520×500
Side box dimensions (mm): 460×470×500
Overall machine weight: 115 kg
Comparison Table of Main Technical Parameters for Calorimeters

Previous page
Next page
Our service network covers the entire country.
24-hour on-call service to resolve issues promptly.
We have service centers nationwide, offering prompt in-home installation and guidance to resolve after-sales issues.