YX-DL8810 Fully Automatic Infrared Sulfur Analyzer

Standard instrument configuration:

1 computer + 1 printer + 1 set of YX-DL8810 host unit

Category:

Elemental Analysis Series

Determination of Total Sulfur in Coal

Keywords:

Analysis instrument

  • Product Description
  • Technical Features
  • Technical Specifications
    • Commodity name: YX-DL8810 Fully Automatic Infrared Sulfur Analyzer
    • 仪器标准配置: 1 computer + 1 printer + 1 set of YX-DL8810 host unit
    • 技术特点: Equipped with an MCPC control module, the instrument provides real-time status monitoring, saves parameter settings, and completes test procedures autonomously without requiring host‑computer intervention, enabling standalone operation and self‑diagnostic alerts, thereby significantly enhancing instrument reliability.

    It is primarily suitable for determining the total sulfur content in solid or liquid substances such as coal, coke, petroleum, combustion residues, cement, rubber, construction materials, and soil.

    Scope of Application

    It is primarily suitable for determining the total sulfur content in solid or liquid substances such as coal, coke, petroleum, combustion residues, cement, rubber, construction materials, and soil.

     

    Conform to the standards

    GB/T 25214 “Determination of Total Sulfur in Coal — Infrared Spectrometric Method”

    GB/T 214 “Method for Determination of Total Sulfur in Coal”

    JJG 1006 “Verification Procedure for Total Sulfur Analyzers in Coal”

    GB/T 483 “General Provisions for Coal Analysis Test Methods”

    GB/T 387 “Method for Determination of Sulfur Content in Dark Petroleum Products”

    ISO 19579 “Solid Mineral Fuels — Determination of Sulfur Content by Infrared Spectrometry”

    Key words:
  • Core Advantages

    Advantage 1: Highly efficient, high-throughput automated testing capabilities

    Using infrared spectroscopic absorption, a single sample can be analyzed in approximately 3 minutes, significantly shortening the testing cycle. The instrument can accommodate up to 70 samples at once and supports cyclical sample loading; additional samples can be added, removed, or inserted at any point during analysis without interrupting the workflow. Paired with the MCPC control module, it enables standalone operation, eliminating the need for host‑computer intervention and fully realizing unattended operation, thereby greatly enhancing the efficiency of batch testing.

    Advantage 2: High-precision, highly stable detection performance

    Equipped with an ultra‑low‑drift infrared cell, the instrument seamlessly integrates three independent gas‑injection ports to perform the entire sequence of gas sealing, purging, and combustion. Combined with a temperature control accuracy of ±1°C, it ensures sulfur measurement resolution down to 0.001%, delivering precise and stable results. The sample‑delivery system features an imported servo‑driven electric cylinder, reducing the likelihood of malfunctions. Imported gas‑path components and an optimized gas‑flow design effectively maintain instrument airtightness while complying with multiple national and international standards, including ISO 19579, ensuring reliable and compliant analytical results.

    Advantage Three: Safe and Environmentally Friendly Lab-Friendly Design

    The instrument supports the external discharge of exhaust gases, thereby preventing harmful emissions from the combustion process from contaminating the laboratory air. It also features real-time monitoring of laboratory temperature and humidity, enabling prompt detection of environmental anomalies, reducing experimental risks, and creating a safer, cleaner working environment for operators.

    Advantage Four: Broad Applicability and Robust IT-Enabled Scalability

    It is applicable to a wide range of sample types and can determine the total sulfur content in various solid and liquid materials, including coal, coke, petroleum, combustion residues, cement, rubber, construction materials, and soil. The measurement range spans 0.01% to 40% and can be extended according to user requirements. Additionally, it can be integrated with laboratory management systems to enable automatic acquisition of balance data, backup of test results, and seamless data upload, thereby meeting the needs for laboratory informationization and standardized management.

     

    Technical Features

    ◎ Equipped with an MCPC control module, the instrument provides real-time status monitoring, saves parameter settings, and completes test procedures autonomously without requiring host‑computer intervention, enabling standalone operation and self‑diagnostic alerts, thereby significantly enhancing instrument reliability.

    ◎ Equipped with an ultra-low-drift infrared cell, it delivers high precision and accuracy while offering simpler operation.

    ◎ Can accommodate 70 samples at a time, enabling unattended operation;

    ◎ Exhaust gases can be vented outdoors, preventing contamination of laboratory air;

    ◎ Enable real-time monitoring of laboratory temperature and humidity;

    ◎ The sample‑feeding system employs an imported servo electric cylinder, ensuring more stable sample delivery and a lower failure rate.

    ◎ It employs a three‑oxygen‑gun nozzle to sequentially perform gas sealing, purging, combustion, and other experimental procedures, ensuring highly accurate test results.

    ◎ Utilizes imported gas‑path components and an optimized gas‑path design to ensure the instrument’s airtightness.

    ◎ Can be integrated with the laboratory management system to ensure that balance data is never stored locally and that test results are backed up and uploaded.

  • Measurement range: 0.01%–40% (expandable upon customer request)

    Test method: Infrared spectroscopic absorption method

    Sulfur measurement resolution: 0.001%

    Working furnace temperature: 1300℃

    Temperature control accuracy: ±1℃

    Sample mass: 300 ± 10 mg (coal, coke), 100 ± 10 mg (petroleum products)

    Sample delivery method: Automatic delivery, sample discard

    Sample capacity: Up to 70 samples can be loaded at once, with cyclical sample loading and the ability to add, delete, or insert test samples at any time.

    Single-sample analysis time: approximately 3 minutes.

    Precision: Conforms to GB/T 25214 “Determination of Total Sulfur in Coal—Infrared Spectrometric Method”

    Accuracy: Within the uncertainty range of the standard sample.

    Power: ≤4 kW

    Power supply: AC 220 V ± 22 V / 50 Hz

    External dimensions (mm): 1240 × 660 × 630

    Instrument weight: 120 kg

     

    Comparison of Main Technical Parameters of Sulfur Analyzers

     

Our service network covers the entire country.


24-hour on-call service to resolve issues promptly.


We have service centers nationwide, offering prompt in-home installation and guidance to resolve after-sales issues.


One-year warranty, lifetime maintenance, and free software upgrades, installation, and commissioning.


24-hour service, free operational training—ensuring customers enjoy five-star, worry-free after-sales support.

Related products


Consult now

If you are interested in our products, please leave your contact information, and we will get in touch with you as soon as possible. Thank you!

Submit Message